Optical Fiber OM2
Referinsje
ITU-T G.651.1 | Skaaimerken fan in 50/125 μm multimode gradearre yndeks glêstriedkabel foar it optyske tagongsnetwurk |
IEC 60794-1-1 | TS EN 6011-1 Fizelkabels - Diel 1-1: Algemiene spesifikaasje - Algemien |
IEC 60794-1-2 IEC 60793-2-10 | TS EN 60116-2-10 Optyske fezels - Diel 2-10: Produktspesifikaasjes - Seksjespesifikaasjes foar kategory A1 multimode fezels |
IEC 60793-1-20 | TS EN 60115-1-20 Optyske fezels - Diel 1-20: Metoaden en testprosedueres - Fibergeometry |
IEC 60793-1-21 | TS EN 60116-1-21 Optyske fezels - Diel 1-21: Mjitmetoaden en testprosedueres - Coatinggeometry |
IEC 60793-1-22 | TS EN 60116-1-22 Optyske fezels - Diel 1-22: Mjitmetoaden en testprosedueres - Lingtemjitting |
IEC 60793-1-30 | TS EN 60136-1-30 Optyske fezels - Diel 1-30: Mjitmetoaden en testprosedueres - Fiberbestindige test |
IEC 60793-1-31 | TS EN 60116-1-31 Optyske fezels - Diel 1-31: Metoaden en testprosedueres - Treksterkte |
IEC 60793-1-32 | TS EN 60115-1-32 Optyske fezels - Diel 1-32: Metoaden en testprosedueres - Stripberens fan coating |
IEC 60793-1-33 | Optyske fezels - Diel 1-33: Mjitmetoaden en testprosedueres - Gefoelichheid foar spanningskorrosje |
IEC 60793-1-34 | TS EN 60116-1-34 Optyske fezels - Diel 1-34: Metoaden en testprosedueres - Fiberkrullen |
IEC 60793-1-40 | TS EN 60116-1-40 Optyske fezels - Diel 1-40: Mjitmetoaden en testprosedueres - Demping |
IEC 60793-1-41 | TS EN 60116-1-41 Optyske fezels - Diel 1-41: Mjitmetoaden en testprosedueres - Bânbreedte |
IEC 60793-1-42 | TS EN 60116-1-42 Optyske fezels - Diel 1-42: Metoaden en testprosedueres - Chromatyske dispersje |
IEC 60793-1-43 | TS EN 60116-1-43 Optyske fezels - Diel 1-43: Mjitmetoaden en testprosedueres - Numeryske aperture |
IEC 60793-1-46 | TS EN 60116-1-46 Optyske fezels - Diel 1-46: Mjitmetoaden en testprosedueres - Monitoring fan feroaringen yn optyske transmittânsje |
IEC 60793-1-47 | TS EN 60116-1-47 Optyske fezels - Diel 1-47: Mjitmetoaden en testprosedueres - Makrobûgingsferlies |
IEC 60793-1-49 | TS EN 60115-1-49 Optyske fezels - Diel 1-49: Mjitmetoaden en testprosedueres - Fertraging differinsjaal modus |
IEC 60793-1-50 | TS EN 60115-1-50 Optyske fezels - Diel 1-50: Metoaden en testprosedueres - Fochtige waarmte (steady state) |
IEC 60793-1-51 | TS EN 60116-1-51 Optyske fezels - Diel 1-51: Mjitmetoaden en testprosedueres - Droege waarmte |
IEC 60793-1-52 | TS EN 60115-1-52 Optyske fezels - Diel 1-52: Metoaden en testprosedueres - Temperatuerferoaring |
IEC 60793-1-53 | TS EN 60115-1-53 Optyske fezels - Diel 1-53: Mjitmetoaden en testprosedueres - Wetterdompeling |
Produkt Yntroduksje
MultiCom ® bending insensitive 50/125 multimode glêstried is in graded yndeks multimode fiber. Dizze optyske glêstried optimisearret de skaaimerken fan 850 nm en 1300 nm bestjoeringsfinsters wiidweidich, en leveret hegere bânbreedte, legere attenuaasje en treflike bûgen ûngefoelige prestaasjes, dy't foldogge oan de gebrûkseasken yn 850 nm en 1300 nm finster. De bûgen ûngefoelige multimode optyske fezels foldogge oan de ISO / IEC 11801 OM2 technyske spesifikaasjes en A1a.1 type optyske fezels yn IEC 60793-2-10.
Performance Features
Krekte brekingsyndeks ferdieling
Outstanding bûgen ferset
Lege attenuation en hege bânbreedte
Produkt Spesifikaasje
Parameter | Betingsten | Units | Wearde |
Optysk (A/B+/B-klasse) | |||
Attenuation | 850 nm | dB/km | ≤2.4/≤2.5/≤2.5 |
1300 nm | dB/km | ≤0.6/≤0.7/≤0.7 | |
Bânbreedte (oerfolle lansearring) | 850 nm | MHz.km | ≥500/≥400/≥200 |
1300 nm | MHz.km | ≥500/≥400/≥200 | |
Numerike diafragma | 0,200±0,015 | ||
Zero dispersion golflingte | nm | 1295-1340 | |
Effektive groep Refractive Index | 850 nm | 1.482 | |
1300 nm | 1.477 | ||
Attenuation Nonuniformity | dB/km | ≤0.10 | |
Partial diskontinuïteit | dB | ≤0.10 | |
Geometrysk | |||
Core Diameter | μm | 50,0±2,5 | |
Core Non-Circularity | % | ≤6.0 | |
Bekleding Diameter | μm | 125±1,0 | |
Cladding Non-Circularity | % | ≤1.0 | |
Core / beklaaiïng konsentriteit flater | μm | ≤1.0 | |
Coating Diameter (ûnkleurd) | μm | 245±7 | |
Coating / beklaaiïng Concentricity Flater | μm | ≤10,0 | |
Miljeu (850nm, 1300nm) | |||
Temperatuer Cycling | -60 ℃ oant+85 ℃ | dB/km | ≤0.10 |
Temperatuer Humidity Cycling | - 10 ℃ oant +85 ℃ oant 98% RH | dB/km | ≤0.10 |
Hege temperatuer & hege luchtvochtigheid | 85 ℃ by 85% RH | dB/km | ≤0.10 |
Wetter Immersion | 23℃ | dB/km | ≤0.10 |
Hege temperatuer Aging | 85 ℃ | dB/km | ≤0.10 |
Meganysk | |||
Bewiis Stress | % | 1.0 | |
kpsi | 100 | ||
Coating Strip Force | Peak | N | 1.3-8.9 |
Trochsneed | N | 1.5 | |
Dynamic Fatigue (Nd) | Typyske wearden | ≥20 | |
Macrobending ferlies | |||
R15 mm×2 t | 850 nm 1300 nm | dB dB | ≤0.1 ≤0.3 |
R7,5 mm×2 t | 850 nm 1300 nm | dB dB | ≤0.2 ≤0.5 |
Levering Lengte | |||
Standert Reel Length | km | 1.1- 17.6 |
Optyske fiber test
Tidens de produksjeperioade moatte alle optyske fezels wurde hifke neffens de folgjende testmetoade.
Ûnderdiel | Test metoade |
Optyske skaaimerken | |
Attenuation | IEC 60793-1-40 |
Chromatyske fersprieding | IEC 60793-1-42 |
Feroaring fan optyske oerdracht | IEC 60793-1-46 |
Differinsjaal modus fertraging | IEC 60793-1-49 |
Bending ferlies | IEC 60793-1-47 |
Modale bânbreedte | IEC 60793-1-41 |
Numerike diafragma | IEC 60793-1-43 |
Geometryske skaaimerken | |
Core diameter | IEC 60793-1-20 |
Bekleding diameter | |
Coating diameter | |
Cladding non-circularity | |
Core / cladding concentricity flater | |
Cladding / coating konsintriteit flater | |
Meganyske skaaimerken | |
Bewiis test | IEC 60793-1-30 |
Fiber krul | IEC 60793-1-34 |
Coating strip krêft | IEC 60793-1-32 |
Miljeu skaaimerken | |
Temperatuer induced attenuation | IEC 60793-1-52 |
Droege waarmte induced attenuation | IEC 60793-1-51 |
Water immersion induced attenuation | IEC 60793-1-53 |
Fochtige waarmte induced attenuation |
Packing
4.1 Optyske glêstried produkten sille wêze skiif-fêstmakke. Eltse skiif kin mar ien manufacturing lingte.
4.2 Cylinder diameter moat net minder as 16cm. Coiled optyske fezels moatte kreas ynrjochte wurde, net los. Beide úteinen fan 'e optyske glêstried wurde fêstmakke en har binnenste ein sil wurde fêstmakke. It kin mear as 2m glêstried opslaan foar ynspeksje.
4.3 De glêstriedproduktplaat sil as folgjend wurde markearre:
A) Namme en adres fan de fabrikant;
B) Produktnamme en standertnûmer;
C) Fibermodel en fabryknûmer;
D) Optical fiber attenuation;
E) Lingte fan glêstried, m.
4.4 Optyske glêstriedprodukten moatte wurde ferpakt foar beskerming, en dan yn 'e ferpakkingsdoaze pleatst, wêrop sil wurde markearre:
A) Namme en adres fan de fabrikant;
B) Produktnamme en standertnûmer;
C) Factory batch oantal glêstried;
D) Bruto gewicht en pakket ôfmjittings;
E) jier en moanne fan produksje;
F) Tekeningen foar ferpakking, opslach en ferfier foar wiet- en fochtresistinsje, omheech en kwetsber.
Befalling
Ferfier en opslach fan glêstried moat omtinken jaan oan:
A) Bewarje yn in pakhús mei keamertemperatuer en relative vochtigheid minder dan 60% fuort fan ljocht;
B) Optyske fibre discs sille net wurde lein of steapele;
C) Luis moat ûnder ferfier wurde bedekt om bleatstelling oan rein, snie en sinne te foarkommen. Behanneling moat foarsichtich wêze om trilling te foarkommen.